The options available to the user in Parameter drop down menu as shown in Figure 1.

Figure 1. 2DH View Option: Model Metrics Menu.

CelerityDisplays the computed celerity for each cell.
CFL Time StepDisplays the Courant-Friedrichs-Lewy (CFL) time step computed for each cell. This is a good guide to the appropriate time step, especially if using the two time level solution. Generally the lower range of the CFL number is the recommended model time step. So for the model shown in Figure 1, a time step of 1.5 seconds is recommended.
Courant #Displays the Courant numbers for the model based on the time step settings of the model. If adaptive time stepping is specified, the time step used for the initial display of the Courant numbers will be 0 seconds. A Courant Calculator is available by setting the focus to the plot and then pressing "T". This allows the user to specify a new time step to be used for the Courant numbers. The Courant number should be less than one for the model time step entered.
FroudeDisplays the computed Froude Number for each cell.
Froude DensityDisplays the computed Froude Density Number for each cell
RichardsonDisplays the computed Richardson Number for each cell.
ReynoldsDisplays the computed Reynolds Number for each cell at the selected time step for each layer. The kinematic viscosity is used for the computations of the Reynolds number.