C7 TIME-RELATED INTEGER PARAMETERS

*

* NTC: NUMBER OF REFERENCE TIME PERIODS IN RUN

* NTSPTC: NUMBER OF TIME STEPS PER REFERENCE TIME PERIOD

* NLTC: NUMBER OF LINEARIZED REFERENCE TIME PERIODS

* NLTC: NUMBER OF TRANSITION REF TIME PERIODS TO FULLY NONLINEAR

* NTCPP: NUMBER OF REFERENCE TIME PERIODS BETWEEN FULL PRINTED OUTPUT

*              TO FILE EFDC.OUT

* NTSTBC: NUMBER OF TIME STEPS BETWEEN USING A TWO TIME LEVEL TRAPEZOIDAL

*                CORRECTION TIME STEP, ** MASS BALANCE PRINT INTERVAL **

* NTCNB: NUMBER OF REFERENCE TIME PERIODS WITH NO BUOYANCY FORCING (NOT USED)

* NTCVB: NUMBER OF REF TIME PERIODS WITH VARIABLE BUOYANCY FORCING

* NTSMMT: NUMBER OF NUMBER OF TIME STEPS TO AVERAGE OVER TO OBTAIN

*                 MASS BALANCE RESIDUALS OR MEAN MASS TRANSPORT VARIABLES (e.g. WASP Linkage)

* NFLTMT: USE 1 (FOR RESEARCH PURPOSES)

* NDRYSTP: MIN NO. OF TIME STEPS A CELL REMAINS DRY AFTER INTIAL DRYING

*                   -NDRYSTP FOR ISDRY=-99 TO ACTIVATE WASTING WATER IN DRY CELLS

* NRAMPUP: NUMBER OF INITIAL LOOPS TO HOLD TIMESTEP CONSTANT FOR DYNNAMIC TIME-STEPPING

* NUPSTEP: MINIMUM NUMBER OF INTERATIONS FOR EACH TIME STEP WHEN GROWING DTDYN

*

C7NTCNTSPTCNLTCNTTCNTCPPNTSTBCNTCNBNTCVBNTSMMTNFLTMTNDRYSTPNRAMPUPNUPSTEP

288640001040028811610002