Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

The General Options window will appear as shown in Figure 2. In the Atmospheric Deposition section, the user can modify the concentrations of different water quality components. To do this, LMC on the Dry Deposition or Wet Deposition buttons then input non-zero values in the table displayed in which the water quality parameters are shown. Click OK to save changes.

Click OK to close the General Options option, then save the model.

Anchor
Figure 2
Figure 2

Figure 2: Wet and Dry Deposition settings

EE will automatically initialize the water quality module using values in the code. However, it is often convenient to initialize a new model using data from another EFDC+ Explorer model with similar conditions. This is done using the Initialize WQ Parameters from File in the Miscellaneous frame as shown in Figure 3. This operation should only be conducted once at the start of the water quality model construction. This process overwrites all of the current model's settings.     

Anchor
Figure 3
Figure 3
Image Added

Figure 3.  Miscellaneous frame.

The user can also configure reaeration options (Figure 4) in this frame. The drop-down menu provides 5 options including constant (WQKRO), constant + wind-generated, O'Connor-Dobbins (1958), Owens & Gibbs (1964), and Owens & Gibbs (modified). Each option will assign a default reaeration value.

Anchor
Figure 4
Figure 4

Image Added

Figure 4.  Reaeration options.

...

The saturation concentration of DO in water increases as pressure increases. This means that water at lower altitudes can hold more dissolved oxygen than water at higher altitudes. Allowance for the effect of elevation on the DO of the waterbody to DO, can be set in DO Saturation Options frame (Figure 5) The user can select different options from the drop-down list of the Formulation option. Options include Garcia and Gordon (1992), Chapra et al. (1997), and Genet et al. (1974). There are three options in the 

...

Elevation Adjustment drop-down, including to not use the elevation adjustment, as well as the Chapra et al. (1997), and Zison et al. (1978) adjustments.

Anchor
Figure 5
Figure 5

Image Added

Figure 5. DO Saturation Options

.