This guidance is based on the assumption the user has a correctly configured and running EFDC+ hydrodynamic model. From this model the user will be guided on how to configure EEMS to export the required files for WASP7/8 water quality simulations. 

Generate WASP linkage output file (*.hyd) from EFDC

We suppose that the user has successfully set up the EFDC hydrodynamic model. The next  The first step is to generate a hydrodynamic linkage file (*.hyd) using for use in the WASP model.  From the Model Control form, go to the Timing/Linkage tab, as shown in Figure 1.

...

After clicking on the Save button, a Select Directory: Write Operation a pop-up will appear to select saving options (refer to Figure 3).  Before project files are saved, the grey box is empty.  This is where EE project files will be listed.  The empty gray box shows that no files have been written yet for the study, as shown in Figure 3

...

Also, in the EFDC+ Multi-Threading frame , set the KMP Offset to set the threads that will be passed over when running the model.  For example, if KMP Offset is set to 2, which means the thread used for the EFDC+ run will start from the 3rd thread.  This can be used to run multiple models on one machine, so the models run on different threads. 

...